Answer
Verified
417k+ views
Hint: To help control and monitor voltage, neutral wires transport currents back to the power source. Its general aim is to act as a road to energy return. Electrical pathways designed to bear fault currents when a power abnormality occurs are ground wires.
- The live cable is directly connected to the power supply company's generators. It holds high voltage current.
- The main power feeder wires are the wires linking the head of the weather service to the building.
Complete answer:
Electrical appliances in a house are connected in parallel as: (i) As the resistance in parallel becomes minimal, each appliance gets maximum voltage. (ii) The operation of other appliances is not compromised if the fuse of one device fails.
- Switches are not connected to neutral wire because if the switches are wired to the neutral cable, there will be no current running into the appliance and it will thus not work.
- A switch is always attached to the live wire in the electrical circuit so that when it is turned off the socket/appliance is not live. The thicker the wire, the greater the current required to melt it and the higher the fuse' rating.'
- If we connect live with a wire with neutral, wire resistance is negligible such that short circuit is induced. The earth wire causes a strong current to pass between the live and earth wires as a failure happens where the live wire attaches to the case. This overheats the fuse that melts the circuit and splits.
Hence, we can see that all the switches of electric appliances are put in the live wire.
So, the correct answer is “Option B”.
Note:
If we link the circuit wires on an outlet to the wrong terminals, the outlet will still operate, but there will be backward polarity. For starters, as this occurs, a lamp will have its bulb socket sleeve energised instead of the little tab inside the socket.
If we connect live with a wire with neutral, wire resistance is negligible such that short circuit is induced.
- The live cable is directly connected to the power supply company's generators. It holds high voltage current.
- The main power feeder wires are the wires linking the head of the weather service to the building.
Complete answer:
Electrical appliances in a house are connected in parallel as: (i) As the resistance in parallel becomes minimal, each appliance gets maximum voltage. (ii) The operation of other appliances is not compromised if the fuse of one device fails.
- Switches are not connected to neutral wire because if the switches are wired to the neutral cable, there will be no current running into the appliance and it will thus not work.
- A switch is always attached to the live wire in the electrical circuit so that when it is turned off the socket/appliance is not live. The thicker the wire, the greater the current required to melt it and the higher the fuse' rating.'
- If we connect live with a wire with neutral, wire resistance is negligible such that short circuit is induced. The earth wire causes a strong current to pass between the live and earth wires as a failure happens where the live wire attaches to the case. This overheats the fuse that melts the circuit and splits.
Hence, we can see that all the switches of electric appliances are put in the live wire.
So, the correct answer is “Option B”.
Note:
If we link the circuit wires on an outlet to the wrong terminals, the outlet will still operate, but there will be backward polarity. For starters, as this occurs, a lamp will have its bulb socket sleeve energised instead of the little tab inside the socket.
If we connect live with a wire with neutral, wire resistance is negligible such that short circuit is induced.
Recently Updated Pages
How many sigma and pi bonds are present in HCequiv class 11 chemistry CBSE
Mark and label the given geoinformation on the outline class 11 social science CBSE
When people say No pun intended what does that mea class 8 english CBSE
Name the states which share their boundary with Indias class 9 social science CBSE
Give an account of the Northern Plains of India class 9 social science CBSE
Change the following sentences into negative and interrogative class 10 english CBSE
Trending doubts
Difference between Prokaryotic cell and Eukaryotic class 11 biology CBSE
Differentiate between homogeneous and heterogeneous class 12 chemistry CBSE
Fill the blanks with the suitable prepositions 1 The class 9 english CBSE
Difference Between Plant Cell and Animal Cell
Which are the Top 10 Largest Countries of the World?
Write a letter to the principal requesting him to grant class 10 english CBSE
10 examples of evaporation in daily life with explanations
Give 10 examples for herbs , shrubs , climbers , creepers
Change the following sentences into negative and interrogative class 10 english CBSE